Eaton MTL-5561 Fire and Smoke Detector Interface – MTL5500 Series
The Eaton MTL-5561 is a two-channel, loop-powered fire and smoke detector interface for conventional detectors installed in hazardous areas. It transfers detector status to safe-area monitoring systems and provides reverse-polarity protection and galvanic isolation for compatible industrial fire detection installations.
Procurement & Technical Support
- Availability
- Contact us to confirm
- Price:
- US$ 238.00
Need help confirming compatibility or finding an alternative? Contact our team with your requirements.
Description
Eaton MTL-5561
MTL5500 Series Fire and Smoke Detector Interface | 2-Channel Loop-Powered Isolator | Intrinsically Safe | DIN-Rail Mounting
Product Detailed Description
The Eaton MTL5561 is a two-channel, loop-powered fire and smoke detector interface designed to connect conventional fire or smoke detectors installed in hazardous areas to monitoring equipment in a safe area. It transfers detector status through changes in the safe-area current, allowing compatible fire and smoke detection circuits to be monitored by a control or alarm system.
The unit supports detector input voltages of 6–30 V DC and a nominal current range of 1–40 mA. It includes reverse-polarity protection and galvanic isolation between safe-area circuits and the power supply. The compact module is designed for 35 mm DIN-rail mounting and is listed for use in appropriately certified hazardous-area installations.
Technical Specifica
| Parameter | Specification |
| Brand | Eaton / MTL Instruments |
| Model | MTL-5561 |
| Product Type | Fire and Smoke Detector Interface |
| Series | MTL5500 |
| Number of Channels | 2, fully floating |
| Operating Principle | Loop-powered |
| Input Voltage | 6–30 V DC |
| Input Current Range | 1–40 mA nominal |
| Maximum Output Voltage | 28 V from 300 Ω |
| Response Time | Settles within 5% of final value in 1.5 ms |
| Galvanic Isolation | 250 V RMS between safe-area circuits and power supply |
| Reverse-Polarity Protection | Yes |
| Hazardous-Area Rating | Suitable for Zone 0, IIC, T4–T6 applications when appropriately certified |
| Safety Capability | SIL 2 for a single device; SIL 3 in suitable redundant configurations, subject to safety manual requirements |
| Mounting | 35 mm T-section DIN rail |
| Dimensions (L × H × W) | 109.8 × 118.8 × 15.8 mm |
| Weight | 150 g |
| Operating Temperature | -20°C to +60°C |
| Country of Origin | United Kingdom, as listed by a distributor; verify the specific unit |
| Product Status | Listed in Eaton’s product catalog; confirm current order availability |
| Replacement Model | MTL5561 is listed as the nearest equivalent for the older MTL5061 |
Replacement Model Introduction
Eaton’s obsolete-product cross-reference lists MTL5561 as the nearest equivalent to the earlier MTL5061. The MTL5561 provides two channels, so confirm the channel count and wiring requirements when replacing an older unit.
This is a predecessor cross-reference, not confirmation that the MTL5561 itself has been discontinued. Verify detector compatibility, current-loop behavior, hazardous-area certification, and safety-system requirements before substitution.
This item is listed for catalogue and inquiry purposes. Availability, condition, revision, warranty coverage, and lead time are confirmed with each quotation.
All items are Distributor Ready-stock Genuine Brand-new Supplying, please inform us if the
Important Application Note
Confirm the detector type, input current, wiring, and applicable hazardous-area certification before ordering. SIL capability depends on the complete safety-system design and the manufacturer’s safety manual; it should not be assumed solely from the product model.
Applications
| Industrial Automation & Control | Machinery & Equipment |
| • Fire detector signal interfaces | • Industrial fire detection systems |
| • Smoke detector monitoring | • Machinery fire alarm circuits |
| • Control-system alarm inputs | • Equipment-room fire monitoring |
| • Hazardous-area detector interfaces | • Process equipment protection |
| • Safety-system status monitoring | • Plant alarm interfaces |
| Power & Electrical Systems | Industrial Applications |
| • Control cabinet alarm interfaces | • Oil and gas facilities |
| • Electrical room fire monitoring | • Chemical processing plants |
| • Fire detection signal isolation | • Power generation facilities |
| • Industrial alarm circuits | • Manufacturing plants |
| • Safety monitoring systems | • Hazardous-area process facilities |
Additional information
| Warranty : | 12 Month |
|---|---|
| Lead Time : | Ready Stock |






Reviews